Publication View

A remark on the number of steady states in a multiple futile cycle (2007)

Abstract
The multisite phosphorylation-dephosphorylation cycle is a motif repeatedly used in cell signaling. This motif itself can generate a variety of dynamic behaviors like bistability and ultrasensitivity without direct positive feedbacks. In this paper, we study the number of positive steady states of a general multisite phosphorylation-dephosphorylation cycle, and how the number of positive steady states varies by changing the biological parameters. We show analytically that (1) for some parameter ranges, there are at least n+1 (if n is even) or n (if n is odd) steady states; (2) there never are more than 2n-1 steady states (in particular, this implies that for n=2, including single levels of MAPK cascades, there are at most three steady states); (3) for parameters near the standard Michaelis-Menten quasi-steady state conditions, there are at most n+1 steady states; and (4) for parameters far from the standard Michaelis-Menten quasi-steady state conditions, there is at most one steady state.. Comment: Resubmit with new results on the upper bound of the number of steady states. 20 pages, 2 figures, See http://www.math.rutgers.edu/~sontag/PUBDIR/index.html for online preprints and reprints of related work

Publication details
Download http://arxiv.org/abs/0704.0036
Repository arXiv (United States)
Keywords Quantitative Biology - Quantitative Methods, Quantitative Biology - Molecular Networks
Type text