Publication View

Third Level Trigger for the Fluorescence Telescopes of the Pierre Auger Observatory (2008)

Abstract
The trigger system for the Auger fluorescence telescopes is implemented in hard- and software for an efficient selection of fluorescence light tracks induced by high-energy extensive air showers. The algorithm of the third stage uses the multiplicity signal of the hardware for fast rejection of lightning events with above 99% efficiency. In a second step direct muon hits in the camera and random triggers are rejected by analyzing the space-time correlation of the pixels. The trigger algorithm was tested with measured and simulated showers and implemented in the electronics of the fluorescence telescopes. A comparison to a prototype trigger without multiplicity shows the superiority of this approach, e.g. the false rejection rate is a factor 10 lower.. Comment: 8 pages, 7 figures, to be published in NIM A; 1 typo corrected

Publication details
Download http://arxiv.org/abs/0807.4421
Repository arXiv (United States)
Keywords Astrophysics
Type text