The CMS barrel calorimeter response to particle beams from 2 to 350 GeV/c (2009)
Abdullin, S., Abramov, V., Acharya, B., Adam, N., Adams, M., Adzic, P., ...
The CMS barrel calorimeter response to particle beams from 2 to 350 GeV/c (2009)
Abdullin, S., Abramov, V., Acharya, B., Adam, N., Adams, M., Adzic, P., ...
The response of the CMS barrel calorimeter (electromagnetic plus hadronic) to hadrons, electrons and muons over a wide momentum range from 2 to 350 GeV/c has been measured. To our knowledge, this is...
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up (2008)
Adzic, P., Alemany-Fernandez, R., Almeida, N., Anagnostou, G., Andelin, D., Anfreville, M., ...
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test...
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up (2008)
Adzic, P, Alemany-Fernandez, R, Almeida, N, Anagnostou, G, Andelin, D, Anfreville, M, ...
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished before installation with cosmic ray muons and test...
Blaha, J, Fay, J, Maurelli, G, Combaret, C, Cartiglia, N, Obertino, M, ...
The Very-Front-End electronics processing signals from photodetectors of the CMS electromagnetic calorimeter have been put through an extensive test programme to guarantee functionality and...
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P., Alemany-Fernandez, R., Almeida, C.B., Almeida, N.M., Anagnostou, G., Anfreville, M.G., ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P., Alemany-Fernandez, R., Almeida, C.B., Almeida, N.M., Anagnostou, G., Anfreville, M.G., ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P., Alemany-Fernandez, R., Almeida, C.B., Almeida, N.M., Anagnostou, G., Anfreville, M.G., ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
Performance of CMS ECAL Very Front End Electronics (2007)
Nardulli, A., Blaha, J., Cartiglia, N., Combaret, C., Djambazov, L., Dröge, M., ...
We report the results of tests of 12880 Very Front End (VFE) readout cards for the barrel of the CMS electromagnetic calorimeter. A thorough test sequence was applied to each card including power-on...
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P, Alemany-Fernandez, R, Almeida, C B, Almeida, N M, Anagnostou, G, Anfreville, M G, ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
CMS physics technical design report, volume II: Physics performance (2007)
Bayatian, G. L., Chatrchyan, S., Hmayakyan, G., Sirunyan, A. M., Adam, W., Bergauer, T., ...
CMS is a general purpose experiment, designed to study the physics of pp collisions at 14 TeV at the Large Hadron Collider ( LHC). It currently involves more than 2000 physicists from more than 150...
Blaha, J., Combaret, C., Fay, J., Maurelli, G.
The Very-Front-End electronics processing signals from photodetectors of the CMS electromagnetic calorimeter have been put through an extensive test programme to guarantee functionality and...
Blaha, J., Cartiglia, N., Combaret, C., Fay, J., Lustermann, W., Maurelli, G., ...
The Very-Front-End cards processing signal from photodetectors of the CMS electromagnetic calorimeter, have been put through extensive test program to guarantee their functionality and reliability....
Blaha, J., Cartiglia, N., Combaret, C., Fay, J., Lustermann, W., Maurelli, G., ...
The Very-Front-End cards processing signal from photodetectors of the CMS electromagnetic calorimeter, have been put through extensive test program to guarantee their functionality and reliability....
Blaha, J., Combaret, C., Fay, J., Maurelli, G.
The Very-Front-End electronics processing signals from photodetectors of the CMS electromagnetic calorimeter have been put through an extensive test programme to guarantee functionality and...
Blaha, J., Cartiglia, N., Combaret, C., Fay, J., Lustermann, W., Maurelli, G., ...
The Very-Front-End cards processing signal from photodetectors of the CMS electromagnetic calorimeter, have been put through extensive test program to guarantee their functionality and reliability....
Blaha, J., Combaret, C., Fay, J., Maurelli, G.
The Very-Front-End electronics processing signals from photodetectors of the CMS electromagnetic calorimeter have been put through an extensive test programme to guarantee functionality and...
Results of the first performance tests * of the CMS electromagnetic calorimeter (2006)
Adzic, P., Alemany-Fernandez, R., Almeida, C. B., Almeida, N. M., Anagnostou, G., Anfreville, M. G., ...
Performance tests of some aspects of the CMS ECAL were carried out on modules of the “barrel” sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to...
Reconstruction of the signal amplitude of the CMS electromagnetic calorimeter (2006)
Adzic, P., Alemany-Fernandez, R., Almeida, C. B., Almeida, N. M., Anagnostou, G., Anfreville, M. G., ...
The amplitude of the signal collected from the PbWO4 crystals of the CMS electromagnetic calorimeter is reconstructed by a digital filtering technique. The amplitude reconstruction has been studied...
Results of the First Performance Tests of the CMS Electromagnetic Calorimeter (2005)
Adzic, P, Alemany-Fernandez, R, Almeida, C B, Almeida, N M, Anagnostou, G, Anfreville, M G, ...
Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to...
Results of the first performance tests of the CMS electromagnetic calorimeter (2005)
Adzic, P., Alemany-Fernandez, R., B. Almeida, C., M. Almeida, N., Anagnostou, G., G. Anfreville, M., ...
Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to...
CMS ECAL Barrel Channel Numbering (2005)
Bartoloni, A., Cavallari, F., Costantini, S., Dafinei, I., Diemoz, M., Longo, E., ...
Results of the first performance tests of the CMS electromagnetic calorimeter (2005)
Adzic, P., Alemany-Fernandez, R., B. Almeida, C., M. Almeida, N., Anagnostou, G., G. Anfreville, M., ...
Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to...
CMS ECAL Barrel Channel Numbering (2005)