The CMS barrel calorimeter response to particle beams from 2 to 350 GeV/c (2009)
Abdullin, S., Abramov, V., Acharya, B., Adam, N., Adams, M., Adzic, P., ...
The CMS barrel calorimeter response to particle beams from 2 to 350 GeV/c (2009)
Abdullin, S., Abramov, V., Acharya, B., Adam, N., Adams, M., Adzic, P., ...
The response of the CMS barrel calorimeter (electromagnetic plus hadronic) to hadrons, electrons and muons over a wide momentum range from 2 to 350 GeV/c has been measured. To our knowledge, this is...
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up (2008)
Adzic, P., Alemany-Fernandez, R., Almeida, N., Anagnostou, G., Andelin, D., Anfreville, M., ...
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test...
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up (2008)
Adzic, P, Alemany-Fernandez, R, Almeida, N, Anagnostou, G, Andelin, D, Anfreville, M, ...
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished before installation with cosmic ray muons and test...
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P., Alemany-Fernandez, R., Almeida, C.B., Almeida, N.M., Anagnostou, G., Anfreville, M.G., ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P., Alemany-Fernandez, R., Almeida, C.B., Almeida, N.M., Anagnostou, G., Anfreville, M.G., ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P., Alemany-Fernandez, R., Almeida, C.B., Almeida, N.M., Anagnostou, G., Anfreville, M.G., ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
The Compact Muon Solenoid Experiment (2007)
th 1998 Study of ECAL energy reconstruction algorithms in test beam data
Results from tests of a Preshower Prototype (2007)
P. Aspell, D. Barney, P. Bloch, S. Reynaud, A. Van Hove, J. Bourotte
Available on CMS information server CMS NOTE 97/032
0 Rejection in the CMS Endcap Electromagnetic Calorimeter- with and (2007)
Without A Preshower, D. Barney, P. Bloch
A detailed Monte-Carlo simulation has been performed to assess the possible rejection
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH (2007)
J. P. Peigneux, M. Schneegans, E. Bateman, S. Burge, D. Cockerill, J. Connolly, ...
Results from tests on matrices of lead tungstate crystals using high energy beams
Energy Resolution of the Barrel of the CMS Electromagnetic Calorimeter (2007)
Adzic, P, Alemany-Fernandez, R, Almeida, C B, Almeida, N M, Anagnostou, G, Anfreville, M G, ...
The energy resolution of the barrel part of the CMS Electromagnetic Calorimeter has been studied using electrons of 20 to 250 GeV in a test beam. The incident electron's energy was reconstructed by...
CMS physics technical design report, volume II: Physics performance (2007)
Bayatian, G. L., Chatrchyan, S., Hmayakyan, G., Sirunyan, A. M., Adam, W., Bergauer, T., ...
CMS is a general purpose experiment, designed to study the physics of pp collisions at 14 TeV at the Large Hadron Collider ( LHC). It currently involves more than 2000 physicists from more than 150...
Detection of muons at 150 GeV/c with a CMS Preshower Prototype (2006)
Barney, D, Bialas, W, Kokkas, P, Manthos, N, Maletic, D, Papadopoulos, I M, ...
The analysis of 150 GeV/c muon data collected during a test of a CMS Preshower prototype is presented. The test took place in 2004 in the H4 beam at CERN. The muon signal extraction is possible after...
The CMS High Level Trigger (2006)
Adam, W, Bergauer, T, Deldicque, C, Ero, J, Frühwirth, R, Jeitler, Manfred, ...
At the Large Hadron Collider at CERN the proton bunches cross at a rate of 40MHz. At the Compact Muon Solenoid experiment the original collision rate is reduced by a factor of O (1000) using a...
Results of the first performance tests * of the CMS electromagnetic calorimeter (2006)
Adzic, P., Alemany-Fernandez, R., Almeida, C. B., Almeida, N. M., Anagnostou, G., Anfreville, M. G., ...
Performance tests of some aspects of the CMS ECAL were carried out on modules of the “barrel” sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to...
Reconstruction of the signal amplitude of the CMS electromagnetic calorimeter (2006)
Adzic, P., Alemany-Fernandez, R., Almeida, C. B., Almeida, N. M., Anagnostou, G., Anfreville, M. G., ...
The amplitude of the signal collected from the PbWO4 crystals of the CMS electromagnetic calorimeter is reconstructed by a digital filtering technique. The amplitude reconstruction has been studied...
Results of the First Performance Tests of the CMS Electromagnetic Calorimeter (2005)
Adzic, P, Alemany-Fernandez, R, Almeida, C B, Almeida, N M, Anagnostou, G, Anfreville, M G, ...
Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to...
Automatic generation and verification of design specifications (2001)
Robinson, N. J., Barney, D., Kearney, P. F., Nikandros, G., Tombs, D. J.
Automatic generation and verification of design specifications (2001)
Robinson, N. J., Barney, D., Kearney, P. F., Nikandros, G., Tombs, D. J.
A Pedagogical Introduction to the CMS Electromagnetic Calorimeter (2000)
Physics at the LHC requires extremely high performance detectors. The CMS electromagnetic calorimeter ( ECAL) has been designed to facilitate the discovery of the Higgs boson, thought to be...
Auffray, Etiennette, Baillon, Paul, Barney, D, Bassompierre, Gabriel, Benhammou, Ya, Blick, A M, ...
Tests of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than...
Measurement of the beauty production cross-section in 350 GeV/c $\pi^-$ -Cu interactions (1998)
Adamovich, M I, Adinolfi, M, Alexandrov, Yu A, Angelini, C, Antinori, Federico, Bacci, Cesare, ...
Using a sample of $10^8$ triggered events, produced in $\pi^-$--$\,$Cu interactions at 350~GeV$/c$, we have identified 26 beauty events. The estimated background in this sample is $0.6 \pm 0.6$...
Auffray, E., Baillon, P., Barney, D., Bassompierre, G., Benhammou, Y., Blick, A., ...
Tests of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than...
Auffray, E., Baillon, P., Barney, D., Bassompierre, G., Benhammou, Y., Blick, A., ...
Tests of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than...
Auffray, E., Baillon, P., Barney, D., Bassompierre, G., Benhammou, Y., Blick, A., ...
Tests of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than...
Alexeev, G., Auffray, E., Baillon, P., Barney, D., Bassompierre, G., Bateman, E., ...
Using matrices of lead tungstate crystals energy resolutions better than 0.6% at 100 GeV have been achieved in the test beam in 1995. It has been demonstrated that a lead tungstate electromagnetic...
Alexeev, G., Auffray, E., Baillon, P., Barney, D., Bassompierre, G., Bateman, E., ...
Using matrices of lead tungstate crystals energy resolutions better than 0.6% at 100 GeV have been achieved in the test beam in 1995. It has been demonstrated that a lead tungstate electromagnetic...
Alexeev, G., Auffray, E., Baillon, P., Barney, D., Bassompierre, G., Bateman, E., ...
Using matrices of lead tungstate crystals energy resolutions better than 0.6% at 100 GeV have been achieved in the test beam in 1995. It has been demonstrated that a lead tungstate electromagnetic...
Alexeev, G, Auffray, Etiennette, Baillon, Paul, Barney, D, Bassompierre, Gabriel, Bateman, E, ...
Using matrices of lead tungstate crystals energy resolutions better than 0.6% at 100 GeV have been achieved in the test beam in 1995. It has been demonstrated that a lead tungstate electromagnetic...
Adamovich, M I, Adinolfi, M, Alexandrov, Yu A, Angelini, C, Barberis, D, Barney, D, ...
A sample of 475 events, in which two charmed-particle decays are observed, is analyzed to determine distributions of two-particle kinematic variables. One charmed particle with $x_F > 0$ is fully...
A low power, large dynamic range, CMOS amplifier and analog memory for capacitive sensors (1996)
Aspell, P, Barney, D, Bloch, P, Bourotte, J, Grabit, R, Jarron, Pierre, ...
This paper has been written to announce the design of a CMOS charge to voltage amplifier and it¹s integration within an analog memory. Together they provide the necessary front end electronics for...
WA92: a fixed target experiment to trigger on and identify beauty particle decays (1996)
Adamovich, M I, Adinolfi, M, Alexandrov, Yu A, Angelini, C, Antinori, Federico, Bacci, Cesare, ...
We describe the detectors and trigger system used in the CERN WA92 experiment. The experiment was designed to study the production and decay of beauty particles from 350 GeV/$c\,$ $\,\pi^-$...
Results from tests on matrices of lead tungstate crystals using high energy beams (1996)
Peigneux, J P, Schneegans, M, Bateman, E, Burge, S R, Cockerill, D J A, Connolly, J, ...
Results from tests on matrices of lead tungstate crystals using high energy beams (1996)
Peigneux, J.P., Schneegans, M., Bateman, E., Burge, S., Cockerill, D., Connolly, J., ...
The performance of lead tungstate crystals using photomultipliers and Si avalanche photodiodes to detect the scintillation light has been studied using high energy electron, pion and muon beams at...
Results from tests on matrices of lead tungstate crystals using high energy beams (1996)
Peigneux, J.P., Schneegans, M., Bateman, E., Burge, S., Cockerill, D., Connolly, J., ...
The performance of lead tungstate crystals using photomultipliers and Si avalanche photodiodes to detect the scintillation light has been studied using high energy electron, pion and muon beams at...
Results from tests on matrices of lead tungstate crystals using high energy beams (1996)
Peigneux, J.P., Schneegans, M., Bateman, E., Burge, S., Cockerill, D., Connolly, J., ...
The performance of lead tungstate crystals using photomultipliers and Si avalanche photodiodes to detect the scintillation light has been studied using high energy electron, pion and muon beams at...
M. Adamovich, M. Adinolfi, Y. Alexandrov, C. Angelini, D. Barberis, D. Barney, ...
A sample of 475 events, in which two charmed-particle decays are observed, is analyzed to determine distributions of two-particle kinematic variables. One charmed particle with x F ? 0 is fully...
Search for the decay D$^{0}$ --> $\mu^{+}\mu^{-}$ (1995)
Adamovich, M I, Adinolfi, M, Alexandrov, Yu A, Angelini, C, Bacci, Cesare, Barberis, D, ...
Study of charm correlations in $\pi^{-}$-N interactions at \Sqrt s $\appprox$ 26 GeV (1995)
Adamovich, M I, Adinolfi, M, Alexandrov, Yu A, Angelini, C, Antinori, Federico, Bacci, Cesare, ...