D. Broggio

Publication List Details

Period

2005 - 2008

Number

11

Co-Authors

Internal dosimetry: towards harmonisation and coordination of research (2008)

Lopez, M.A., Etherington, G., Castellani, C.M., Franck, D., Hurtgen, Christian, Marsh, J.W., ...

The CONRAD Project is a Coordinated Network for Radiation Dosimetry funded by the European Commission 6th Framework Programme. The activities developed within CONRAD Work Package 5 (‘Coordination...

Internal dosimetry: towards harmonisation and coordination of research (2008)

Lopez, M. A., Etherington, G., Castellani, C. M., Franck, D., Hurtgen, C., Marsh, J. W., ...

The CONRAD Project is a Coordinated Network for Radiation Dosimetry funded by the European Commission 6th Framework Programme. The activities developed within CONRAD Work Package 5 (‘Coordination...

Polyvinyltoluene scintillators for relative ion dosimetry: An investigation with Helium, Carbon and Neon beams (2007)

Broggio, D., Barillon, R., Jung, J.M., Yasuda, N., Yamauchi, T., Kitamura, H., ...

We present a dosimeter prototype, devoted to ion beam dosimetry, tested with Helium, Carbon and Neon ions having an equivalent range in water of 150 mm. A polyvinyltoluene based plastic scintillator...

Polyvinyltoluene scintillators for relative ion dosimetry: An investigation with Helium, Carbon and Neon beams (2007)

Broggio, D., Barillon, R., Jung, J.M., Yasuda, N., Yamauchi, T., Kitamura, H., ...

We present a dosimeter prototype, devoted to ion beam dosimetry, tested with Helium, Carbon and Neon ions having an equivalent range in water of 150 mm. A polyvinyltoluene based plastic scintillator...

Polyvinyltoluene scintillators for relative ion dosimetry: An investigation with Helium, Carbon and Neon beams (2007)

Broggio, D., Barillon, R., Jung, J.M., Yasuda, N., Yamauchi, T., Kitamura, H., ...

We present a dosimeter prototype, devoted to ion beam dosimetry, tested with Helium, Carbon and Neon ions having an equivalent range in water of 150 mm. A polyvinyltoluene based plastic scintillator...

OEDIPE: a new graphical user interface for fast construction of numerical phantoms and MCNP calculations (2007)

Franck, D., De Carlan, L., Pierrat, N., Broggio, D., Lamart, S.

Although great efforts have been made to improve the physical phantoms used to calibrate in vivo measurement systems, these phantoms represent a single average counting geometry and usually contain a...

Ion-induced degradation of BC-418 scintillation yield (2005)

Broggio, D., Jung, J.M., Barillon, R., Yamauchi, T.

We report results concerning the degradation of the scintillation yield of the plastic scintillator BC-418 under ion beam irradiation. Lithium, carbon and iodine ions have been used at different...

Ion-induced degradation of BC-418 scintillation yield (2005)

Broggio, D., Jung, J.M., Barillon, R., Yamauchi, T.

We report results concerning the degradation of the scintillation yield of the plastic scintillator BC-418 under ion beam irradiation. Lithium, carbon and iodine ions have been used at different...