D. Hensel

Publication List Details

Period

1987 - 2007

Number

9

Co-Authors

Numerical optimization of the ignitor for large caliber weapons. (1988)

Hensel, D., Heiser, R.

Die Anzündung in großkalibrigen Rohrwaffen hängt empfindlich von der Wechselwirkung des Anzündelements mit dem Treibladungspulver (TLP) ab. Eine ungünstige Anzündung kann zu...

Numerical and experimental investigation of the ignition process of a 105-mm tank gun round (1987)

Gütlin, E., Hensel, D., Heiser, R., Zimmermann, G.

In order to elucidate the process of the generation of pressure waves appearing under adverse conditions in tank guns, investigations of the ignition process of a 105-mm tank gun round were carried...

Evaluation of a lysis direct plating method for pediatric blood cultures.

Welch, D F, Scribner, R K, Hensel, D

The Isolator 1.5 Microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) is a commercially available blood culture system for use in pediatrics. The methodology is based on blood...

Evaluation of Bactogen and Phadebact for detection of Haemophilus influenzae type b antigen in cerebrospinal fluid.

Welch, D F, Hensel, D

Latex agglutination and coagglutination tests are commercially available as Bactogen and the Phadebact Haemophilus Test, respectively. We evaluated both for the detection of Haemophilus influenzae...

Evaluation of the Phadebact CSF test for detection of the four most common causes of bacterial meningitis.

Drow, D L, Welch, D F, Hensel, D, Eisenach, K, Long, E, Slifkin, M

A five-center collaborative study was undertaken to determine the suitability of the Phadebact CSF test kit and the Phadebact group B Streptococcus reagent for routine use by clinical laboratories to...

Evaluation of a lysis direct plating method for pediatric blood cultures.

Welch, D F, Scribner, R K, Hensel, D

The Isolator 1.5 Microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) is a commercially available blood culture system for use in pediatrics. The methodology is based on blood...

Evaluation of Bactogen and Phadebact for detection of Haemophilus influenzae type b antigen in cerebrospinal fluid.

Welch, D F, Hensel, D

Latex agglutination and coagglutination tests are commercially available as Bactogen and the Phadebact Haemophilus Test, respectively. We evaluated both for the detection of Haemophilus influenzae...

Evaluation of the Phadebact CSF test for detection of the four most common causes of bacterial meningitis.

Drow, D L, Welch, D F, Hensel, D, Eisenach, K, Long, E, Slifkin, M

A five-center collaborative study was undertaken to determine the suitability of the Phadebact CSF test kit and the Phadebact group B Streptococcus reagent for routine use by clinical laboratories to...