Dynamical interpretation of extreme events: Predictions and predictability (2006)
Kantz, H., Altmann, E., Hallerberg, S., Holstein, D., Riegert, A.
Hybrid Performance of the Pierre Auger Observatory and Reconstruction of Hybrid Events (2003)
Kick, B., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
The Pierre Auger Observatory is a``hybrid'' UHECR detector. The surface detector (SD) and air fluorescence detector (FD) of the observatory are designed for observation of cosmic ray showers in...
Roth, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The surface detector (SD) array of the southern Pierre Auger Observatory will consist of a triangular grid of 1600 water Cherenkov tanks with 1.5 km spacing. For zenith angles less than 60deg the...
Processing of the Signals from the Surface Detectors of the Pierre - Auger Observatory (2003)
Suomijarvi, T., Roberts, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
The detectors of the surface array of the Pierre Auger Observatory are water Cherenkov tanks. The signals from each tank are read out using three photomultipliers. The energy of the primary particle...
Calibration of the Pierre Auger fluorescence detector (2003)
Roberts, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The absolute calibration of an air fluorescence detector (FD) is an important element in correctly determining the energy of detected cosmic rays. The absolute calibration relates the flux of photons...
Argiro, S., Clay, W., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
The Pierre Auger Observatory is designed to elucidate the origin and nature of Ultra High Energy Cosmic Rays using a hybrid detection technique. A first run of data taking with a prototype version of...
Ghia, P-L., Mostafa, M.A., Fick, B., Ave, M., Letessier, A., Bertou, X., ...
Three months of data taken by the Engineering Array Surface Detector of the Pierre Auger Observatory have been analyzed with the aim of setting a procedure for the study of showers at E_0 ~ 10^18 eV....
Atmospheric Monitoring for the Pierre Auger Fluorescence Detector (2003)
Mostafa, M.A., Fick, B., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
Major uncertainties in the fluorescence energy measurement come from the precision of various atmospheric transmission, air Cerenkov subtraction, light multiple-scattering and cloud corrections. The...
The Anisotropy Search Program For the Pierre Auger Observatory (2003)
Clay, W., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The Pierre Auger Southern Observatory in Argentina has begun taking data as it is being developed up to a final enclosed area of 3000 square kilometres. A key aspect of the project is to provide...
A Study Of Very Inclined Showers In The Pierre Auger Observatory (2003)
Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., Altmann, E., ...
The Engineering Array of the Auger Observatory has been running successfully since 2001 and inclined showers have been recorded from the start. We have analysed the events with zenith angle $>$...
Hybrid Performance of the Pierre Auger Observatory and Reconstruction of Hybrid Events (2003)
Kick, B., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
The Pierre Auger Observatory is a``hybrid'' UHECR detector. The surface detector (SD) and air fluorescence detector (FD) of the observatory are designed for observation of cosmic ray showers in...
Cosmic rays at the highest energies and the Pierre Auger Observatory (2003)
Bluemer, J., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
Roth, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The surface detector (SD) array of the southern Pierre Auger Observatory will consist of a triangular grid of 1600 water Cherenkov tanks with 1.5 km spacing. For zenith angles less than 60deg the...
Processing of the Signals from the Surface Detectors of the Pierre - Auger Observatory (2003)
Suomijarvi, T., Roberts, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
The detectors of the surface array of the Pierre Auger Observatory are water Cherenkov tanks. The signals from each tank are read out using three photomultipliers. The energy of the primary particle...
Calibration of the Pierre Auger fluorescence detector (2003)
Roberts, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The absolute calibration of an air fluorescence detector (FD) is an important element in correctly determining the energy of detected cosmic rays. The absolute calibration relates the flux of photons...
Argiro, S., Clay, W., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
The Pierre Auger Observatory is designed to elucidate the origin and nature of Ultra High Energy Cosmic Rays using a hybrid detection technique. A first run of data taking with a prototype version of...
Ghia, P-L., Mostafa, M.A., Fick, B., Ave, M., Letessier, A., Bertou, X., ...
Three months of data taken by the Engineering Array Surface Detector of the Pierre Auger Observatory have been analyzed with the aim of setting a procedure for the study of showers at E_0 ~ 10^18 eV....
Atmospheric Monitoring for the Pierre Auger Fluorescence Detector (2003)
Mostafa, M.A., Fick, B., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
Major uncertainties in the fluorescence energy measurement come from the precision of various atmospheric transmission, air Cerenkov subtraction, light multiple-scattering and cloud corrections. The...
The Anisotropy Search Program For the Pierre Auger Observatory (2003)
Clay, W., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The Pierre Auger Southern Observatory in Argentina has begun taking data as it is being developed up to a final enclosed area of 3000 square kilometres. A key aspect of the project is to provide...
A Study Of Very Inclined Showers In The Pierre Auger Observatory (2003)
Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., Altmann, E., ...
The Engineering Array of the Auger Observatory has been running successfully since 2001 and inclined showers have been recorded from the start. We have analysed the events with zenith angle $>$...
Hybrid Performance of the Pierre Auger Observatory and Reconstruction of Hybrid Events (2003)
Kick, B., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
The Pierre Auger Observatory is a``hybrid'' UHECR detector. The surface detector (SD) and air fluorescence detector (FD) of the observatory are designed for observation of cosmic ray showers in...
Cosmic rays at the highest energies and the Pierre Auger Observatory (2003)
Bluemer, J., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
Roth, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The surface detector (SD) array of the southern Pierre Auger Observatory will consist of a triangular grid of 1600 water Cherenkov tanks with 1.5 km spacing. For zenith angles less than 60deg the...
Processing of the Signals from the Surface Detectors of the Pierre - Auger Observatory (2003)
Suomijarvi, T., Roberts, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
The detectors of the surface array of the Pierre Auger Observatory are water Cherenkov tanks. The signals from each tank are read out using three photomultipliers. The energy of the primary particle...
Calibration of the Pierre Auger fluorescence detector (2003)
Roberts, M., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The absolute calibration of an air fluorescence detector (FD) is an important element in correctly determining the energy of detected cosmic rays. The absolute calibration relates the flux of photons...
Argiro, S., Clay, W., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
The Pierre Auger Observatory is designed to elucidate the origin and nature of Ultra High Energy Cosmic Rays using a hybrid detection technique. A first run of data taking with a prototype version of...
Ghia, P-L., Mostafa, M.A., Fick, B., Ave, M., Letessier, A., Bertou, X., ...
Three months of data taken by the Engineering Array Surface Detector of the Pierre Auger Observatory have been analyzed with the aim of setting a procedure for the study of showers at E_0 ~ 10^18 eV....
Atmospheric Monitoring for the Pierre Auger Fluorescence Detector (2003)
Mostafa, M.A., Fick, B., Ave, M., Letessier, A., Bertou, X., Deligny, O., ...
Major uncertainties in the fluorescence energy measurement come from the precision of various atmospheric transmission, air Cerenkov subtraction, light multiple-scattering and cloud corrections. The...
The Anisotropy Search Program For the Pierre Auger Observatory (2003)
Clay, W., Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., ...
The Pierre Auger Southern Observatory in Argentina has begun taking data as it is being developed up to a final enclosed area of 3000 square kilometres. A key aspect of the project is to provide...
A Study Of Very Inclined Showers In The Pierre Auger Observatory (2003)
Ave, M., Letessier, A., Bertou, X., Deligny, O., Lachaud, C., Altmann, E., ...
The Engineering Array of the Auger Observatory has been running successfully since 2001 and inclined showers have been recorded from the start. We have analysed the events with zenith angle $>$...
Status of the Auger Engineering Array (2001)
Allekote, I., Barbosa, A. F., Kleinfeller, J., Altmann, E., Alvarez, P., Bauleo, P., ...
Layout of the Pierre Auger Observatory (2001)
Etchegoyen, A., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Eusebi, R., ...
The Auger Fluorescence Detector Electronics (2001)
Gemmeke, H., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
Survey of the Pierre Auger Observatory (2001)
Dova, M-T., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
The Hybrid Aperture and Precision of the Pierre Auger Observatory (2001)
Dawson, B., Sommers, P., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
Surface Detector Electronics for the Pierre Auger Observatory (2001)
Suomijarvi, T., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
Surface Detector Calibration for the Auger Observatory (2001)
Salazar, H., Nellen, L., Villasenor, L., Altmann, E., Alvarez, P., Bauleo, P., ...
Communications in the Pierre Auger Observatory (2001)
Clark, P.D.J., Nitz, D., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
Atmospheric Monitoring for the Auger Fluorescence Detector (2001)
Matthews, J.A.J., Clay, R., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
A PLD Implementation of the Pierre Auger Observatory First Level Trigger (2001)
Szadkowski, Z., Nitz, D., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
Implementation of the first level trigger for the Auger Observatory (2001)
Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., Eusebi, R., ...
Surface detector construction and installation at the Auger Observatory (2001)
Escobar, C.O., Filevich, A., Mazur, P.O., Altmann, E., Alvarez, P., Bauleo, P., ...
Neutrino sensitivity and backgroung rejection of the Auger Observatory (2001)
Letessier, A., Bertou, X., Deligny, O., Lachaud, C., Altmann, E., Alvarez, P., ...
The aperure, sensitivity and precision of the Auger Fluorescence Detector (2001)
Cester, R., Ave, M., Lloyd-Evans, J., Watson, A.A, Billoir, P., Bertou, X., ...
The aperture and precision of the Auger surface array (2001)
Ave, M., Lloyd-Evans, J., Watson, A.A, Billoir, P., Bertou, X., Dagoret-Campagne, S., ...
Photon/hadron separation with the AUGER Observatory (2001)
Billoir, P., Bertou, X., Dagoret-Campagne, S., Letessier-Selvon, A., Revenu, B., Etchegoyen, A., ...
Status of the Auger Engineering Array (2001)
Allekote, I., Barbosa, A. F., Kleinfeller, J., Altmann, E., Alvarez, P., Bauleo, P., ...
Layout of the Pierre Auger Observatory (2001)
Etchegoyen, A., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Eusebi, R., ...
The Auger Fluorescence Detector Electronics (2001)
Gemmeke, H., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
Survey of the Pierre Auger Observatory (2001)
Dova, M-T., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
The Hybrid Aperture and Precision of the Pierre Auger Observatory (2001)
Dawson, B., Sommers, P., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
Surface Detector Electronics for the Pierre Auger Observatory (2001)
Suomijarvi, T., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
Surface Detector Calibration for the Auger Observatory (2001)
Salazar, H., Nellen, L., Villasenor, L., Altmann, E., Alvarez, P., Bauleo, P., ...
Communications in the Pierre Auger Observatory (2001)
Clark, P.D.J., Nitz, D., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
Atmospheric Monitoring for the Auger Fluorescence Detector (2001)
Matthews, J.A.J., Clay, R., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
A PLD Implementation of the Pierre Auger Observatory First Level Trigger (2001)
Szadkowski, Z., Nitz, D., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., ...
Implementation of the first level trigger for the Auger Observatory (2001)
Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., Eusebi, R., ...
Surface detector construction and installation at the Auger Observatory (2001)
Escobar, C.O., Filevich, A., Mazur, P.O., Altmann, E., Alvarez, P., Bauleo, P., ...
Neutrino sensitivity and backgroung rejection of the Auger Observatory (2001)
Letessier, A., Bertou, X., Deligny, O., Lachaud, C., Altmann, E., Alvarez, P., ...
The aperure, sensitivity and precision of the Auger Fluorescence Detector (2001)
Cester, R., Ave, M., Lloyd-Evans, J., Watson, A.A, Billoir, P., Bertou, X., ...
The aperture and precision of the Auger surface array (2001)
Ave, M., Lloyd-Evans, J., Watson, A.A, Billoir, P., Bertou, X., Dagoret-Campagne, S., ...
Photon/hadron separation with the AUGER Observatory (2001)
Billoir, P., Bertou, X., Dagoret-Campagne, S., Letessier-Selvon, A., Revenu, B., Etchegoyen, A., ...
The Pierre Auger Observatory (2000)
Zavrtanik, D., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
The Pierre Auger Observatory (2000)
Zavrtanik, D., Altmann, E., Alvarez, P., Bauleo, P., Bonifazi, C., Etchegoyen, A., ...
Ronner, E, Zijnen, P, Altmann, E, Molhoek, P.G, Van Der Wieken, L.R, ...
Aims Thrombolytic therapy restores coronary patency in patients with acute myocardial infarction, although normal perfusion (TIMI 3 flow) is not achieved in all patients. In an attempt to improve...
PAVONE, V, DIBLASIO, B, LOMBARDI, A, MAGLIO, O, ISERNIA, C, PEDONE, C, ...
The crystal and molecular structure of the fully protected dipeptide Boc-Val-(S)-alpha-MeSer-OMe has been determined by X-ray diffraction techniques. Crystals grown from ethyl acetate/n-pentane...
ALTMANN, KH, ALTMANN, E, MUTTER, M
The conformational properties of four model peptides of the general formula Ac-Tyr-Xaa-Yaa-Zaa-Ala-Lys-Glu-Ala-Ala-Glu-Lys-Ala-Zaa-Yaa-Xaa-Lys-NH, (Xaa-Yaa-Zaa=Ala-Ala-(R)-Asp(2-Me), 1;...
NEBEL, K, ALTMANN, E, MUTTER, M, BARDI, R, PIAZZESI, AM, CRISMA, M, ...
The molecular structures of four protected isovaline- (Iva-)containing peptides to the pentamer level have been determined by x-ray diffraction. The peptides are t-Boc-Ala(S)-Iva-Ala-OMe (t-Boc :...
ALTMANN, E, NEBEL, K, MUTTER, M
A new route to completely protected alpha-methylated alpha-amino acids starting from alanine is described (see Scheme). These derivatives, which are obtained via base-catalyzed opening of the...