J. P. Delahaye

Publication List Details

Period

1984 - 2008

Number

73

Co-Authors

CHAPTER 11 The Iterated Lift Dilemma How to Establish Meta-Cooperation with your Opponent (2008)

J. P. Delahaye, P. Mathieu, B. Beaufils

A very small change in the Iterated Prisoner’s Dilemma (IPD) payoff matrix leads to an iterated game called the Iterated Lift Dilemma 1 the properties of which are very different from those of the...

CLIC 2008 Parameters (2008)

Braun, H, Corsini, R, Delahaye, J P, De Roeck, A, Döbert, S, Ferrari, A, ...

This note presents the CLIC parameter set as of beginning 2008 and describes the different subsystems,pointing out how the design of the different components is driven. This design emerged from an...

Exploring ultra-low β* values in ATF2 - R&D Programme proposal (2008)

Angal-Kalinin, D., Bai, S., Bambade, P., Braun, H., Delahaye, J.P., Gao, J., ...

We propose to explore the beam sizes and performance of the ATF2 Final Focus System for reduced IP beta functions up to a factor between 2 and 4 below its design. The results will demonstrate the...

Exploring ultra-low β* values in ATF2 - R&D Programme proposal (2008)

Angal-Kalinin, D., Bai, S., Bambade, P., Braun, H., Delahaye, J.P., Gao, J., ...

We propose to explore the beam sizes and performance of the ATF2 Final Focus System for reduced IP beta functions up to a factor between 2 and 4 below its design. The results will demonstrate the...

Exploring ultra-low β* values in ATF2 - R&D Programme proposal (2008)

Angal-Kalinin, D., Bai, S., Bambade, P., Braun, H., Delahaye, J.P., Gao, J., ...

We propose to explore the beam sizes and performance of the ATF2 Final Focus System for reduced IP beta functions up to a factor between 2 and 4 below its design. The results will demonstrate the...

CLIC-LHC Based FEL-Nucleus Collider: Feasibility and Physics Search Potential (2005)

Braun, H., Corsini, R., Delahaye, J. P., Guliyev, E., Ozcan, A., Sultansoy, S., ...

The feasibility of a CLIC-LHC based FEL-nucleus collider is investigated. It is shown that the proposed scheme satisfies all requirements of an ideal photon source for the Nuclear Resonance...

R and D for the Feasibility Study of CLIC Technology (2004)

Braun, H, Delahaye, J P, Geschonke, Günther, Guignard, Gilbert, Hübner, K, Wilson, Ian H

An overview is given of the necessary R&D and particularly of the CLIC test facility CTF3 which is presently under construction for demonstrating the key issues related to the CLIC technology and to...

The Study of a European Neutrino Factory Complex (2003)

Gruber, P, Aleksa, Martin, Amand, J F, Autin, Bruno, Baldy, J L, Benedikt, Michael, ...

The Neutrino Factory is a new concept for an accelerator that produces a high-intensity, high-energy beam of electron and muon neutrinos - the ultimate tool for neutrino oscillation studies and the...

CTF3 Design Report: Preliminary Phase (2001)

Allard, D, Bartholome, B, Bernard, M, Bertuzzi, J P, Bienvenu, G, Bonzano, R, ...

The design of CLIC is based on a two-beam scheme, where the short pulses of high power 30 GHz RF are extracted from a drive beam running parallel to the main beam. The 3rd generation CLIC Test...

Increasing the Proton Intensity of PS and SPS (2001)

Cappi, R, Cornelis, Karel, Delahaye, J P, Garoby, R, Haseroth, H, Hübner, K, ...

Recently, a series of meetings were organised with PS and SPS participants, to discuss the possibilities of increasing the proton intensity on the SPS targets (with particular emphasis to CNGS) as...

CLIC: a Two-Beam Multi-TeV $e\pm$ Linear Collider (2000)

Delahaye, J P, Wilson, Ian H, Assmann, R W, Becker, F, Bossart, Rudolf, Braun, H, ...

The CLIC study of a high-energy (0.5 - 5 TeV), high-luminosity (1034 - 1035 cm-2 sec-1) e± linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures...

A Review of Possible Future High-Energy Colliders for the Post-LHC Era (1999)

Delahaye, J P

A review of the studies being conducted by various laboratories and collaborations in order to determine and optimise the next generation of particle accelerators for physics at the high energy...

CLIC, a Multi-TeV $e^{\pm}$ Linear Collider (1999)

Delahaye, J P, Wilson, Ian H, Bossart, Rudolf, Braun, Hans Heinrich, Carron, G, Coosemans, Williame, ...

The CLIC study of a high energy (0.5 - 5 TeV), high luminosity (1034 - 1035 cm-2 sec-1) e± linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures...

CLIC Main Linac Beam-Loading Compensation by Drive Beam Phase Modulation (1999)

Corsini, R, Delahaye, J P, Syratchev, I V

The CLIC final focus momentum acceptance of ± 0.5 % limits the bunch-to-bunch energy variation in the main beam to less than ± 0.1 %, since the estimated single-bunch contribution is ± 0.4 %. On...

The CLIC Study of a Multi-TeV $e^\pm$ Linear Collider (1999)

Bossart, Rudolf, Braun, Hans Heinrich, Carron, G, Coosemans, Williame, Corsini, R, D'Amico, T E, ...

The progress of the Compact LInear Collider (CLIC) study of a multi-TeV (0.5 - 5 TeV) high-luminosity (5'1033 to 1.5'1035 cm-2 sec-1) e± linear collider based on Two-Beam Acceleration (TBA) is...

Demonstration of two-beam and 30 GHz power production in the CLIC test facility (1998)

Bossart, Rudolf, Braun, Hans Heinrich, Carron, G, Chanudet, M, Chautard, F, Delahaye, J P, ...

The Compact Linear Collider (CLIC) Test Facility (CTF II) at CERN has recently demonstrated Two-Beam power production and acceleration at 30 GHz. With 41 MW of 30 GHz power produced in 14 ns pulses...

Demonstration of two-beam acceleration in CTF II (1998)

Bossart, Rudolf, Braun, Hans Heinrich, Carron, G, Chanudet, M, Chautard, F, Delahaye, J P, ...

The second phase of the Compact LInear Collider (CLIC) Test Facility (CTF II) at CERN has demon-strated the feasibility of two-beam acceleration at 30 GHz using a high-charge drive beam, running...

Scaling Laws for Normal Conducting $e^{\pm}$ Linear Colliders (1998)

Delahaye, J P, Guignard, Gilbert, Raubenheimer, T O, Wilson, Ian H

Design studies of a future TeV e± Linear Collider (TLC) are presently being made by five major laboratories within the framework of a world-wide collaboration. A figure of merit is defined which...

CLIC, a 0.5 to 5 TeV e$^{\pm}$ Compact Linear Collider (1998)

Delahaye, J P, Bossart, Rudolf, Braun, Hans Heinrich, Carron, G, Chautard, F, Coosemans, Williame, ...

The CLIC study of a high energy (0.5 - 5 TeV), high luminosity (10^34 - 10^35 cm^-2 sec^-1) e± linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting...

A new method of RF power generation for two-beam linear colliders (1998)

Braun, H, Corsini, R, D'Amico, T E, Delahaye, J P, Guignard, Gilbert, Johnson, C, ...

In this paper we discuss a new approach to two-beam acceleration. The energy for RF production is initially stored in a long-pulse electron beam which is efficiently accelerated to about 1.2 GeV by a...

Away-Day (1998)

Delahaye, J P

A review of the CLIC parameters at 1 and 3 TeV (5 TeV?) in order to re-define new "target' parameters taking into account: - the new model of the multibunch accelerating structure, - the new drive...

The CLIC Multi-Drive Beam Scheme (1998)

Corsini, R, Delahaye, J P

The CLIC study of an e+ / e- linear collider in the TeV energy range is based on Two-Beam Acceleration (TBA) in which the RF power needed to accelerate the beam is extracted from high intensity...

Scaling Laws for $e^+ e^-$ Linear Colliders (1998)

Delahaye, J P, Guignard, Gilbert, Raubenheimer, T O, Wilson, Ian H

Design studies of a future TeV e+e- Linear Collider (TLC) are presently being made by five major laboratories within the framework of a world-wide collaboration. A figure of merit is defined which...

A Multi-Drive Beam Scheme for Two-Beam Acceleration in a TeV Linear Collider (1997)

Corsini, R, Delahaye, J P, Johnson, C, Millich, Antonio, Riche, A J

The Compact Linear Collider (CLIC) study of an e+/e- linear collider in the TeV energy range is based on Two-Beam Acceleration (TBA) in which the overall RF power needed to accelerate the beam is...

A 30 GHz 5-TeV Linear Collider (1997)

Delahaye, J P, Guignard, Gilbert, Irwin, J, Raubenheimer, T O, Ruth, Ronald D, Wilson, Ian H, ...

We present parameters for a linear collider with a $3$ to $5$ TeV center-of-mass energy that utilizes conventional rf technology operating at a frequency around 30 GHz. We discuss the scaling laws...

Design Issues of TeV Linear Colliders (1996)

Delahaye, J P

Within the frame work of a world-wide collabora-tion, various possible approaches for Linear Colliders in the TeV energy range (TLC) and high luminosity (~ 1034 cm-2 sec-1) are explored in different...

Results from the CLIC Test Facility (1996)

Braun, H, Aulenbacher, K, Bossart, Rudolf, Chautard, F, Corsini, R, Delahaye, J P, ...

In order to study the principle of the Compact Linear Collider (CLIC) based on the Two Beam Acceleration (TBA) scheme at high frequency, a CLIC Test Facility (CTF) has been set-up at CERN. After four...

The risk of infective endocarditis after cardiac surgical and interventional procedures (1995)

De Gevigney, G., Pop, C., Delahaye, J. P.

The risk of infective endocarditis after cardiac surgery relates mainly to the risk of infective endocarditis on prosthetic valves. The frequency of prosthetic infective endocarditis varies according...

Compression and Sequence Comparison (1994)

O. Delgrange, J. P. Delahaye, M. Dauchet

reference one. This second use of DNA compression yields to an objective and clearly understandable measurement of sequences similarity (see [6]). In the first part, we outline the compression basic...

Chlamydial endocarditis: a report on ten cases (1992)

ETIENNE, J., ORY, D., THOUVENOT, D., EB, F., RAOULT, D., LOIRE, R., ...

Over the period 1983–1990, 10 cases of infective native-valve endocarditis as a result of Chlamydia were seen. All patients were men, with a mean age of 42 years, and none had a history of exposure...

Natural history of severe mitral regurgitation (1991)

Delahaye, J. P., Gare, J. P., Viguier, E., Delahaye, F., De Gevigney, G., Milon, H.

The aim of this retrospective study was to review the outcome of 216paticnis (pts), investigated for severe mitral regurgitation (MR) between January 1980 and December 1987. .Dtfinition of...

Cerebrovascular accidents in infective endocarditis: role of anticoagulation (1990)

DELAHAYE, J. P., PONCET, PH., MALQUARTI, V., BEAUNE, J., MANN, J. M.

Anticoagulation is still a matter of debate in infective endocarditis, since it can increase the risk of complications, mostly neurological. In our series of 269 patients with native valve...

Infective endocarditis on stenotic aortic valves (1988)

Delahaye, J. P., Loire, R., Milon, H., De Gevigney, G. Durand, Delahaye, F., Boissonnat, P., ...

Charts were reviewed of 42 adult patients (27 men, 15 women, mean age 55 years, with 17 older than 60) hospitalized and/or autopsied between 1970 and 1986 with diagnosis of definite or highly...

W) VARIATION OF THE DAMPING PARTITION NUMBERS WITH PARTICLE ENERGY DEVIATION* (1984)

J. P. Delahaye

Until now, calculation of the rates of change of the damping partition numbers(‘~21 with particle energy took into account only the effects of quadrupole fieldst31. It has been foundt41, however,...

Bacterial endocarditis presenting as acute vertebral osteomyelitis: 14 cases (1984)

Ninet, J., Gayet, J. L., Etienne, J., Bonvoisin, B., Vignon, E., Berthou, J. D., ...

Association between bacterial endocarditis (BE) and vertebral osteomyelitis (VO) has infrequently been noted. In a retrospective analysis of BE (280 cases) and VO (150 cases) 14 cases were found to...

Prognosis of native valve infective endocarditis: a review of 253 cases (1984)

Malquarti, V., Saradarian, W., Etienne, J., Milon, H., Delahaye, J. P.

Forty years after the first ‘recoveries’ obtained by antibiotherapy and twenty years after the first success of early valvular replacement, the mortality of infective endocarditis (IE) is still...

Clic Test Facility Developments And Results

Bossart Braun Chautard, R. Bossart, H. Braun, F. Chautard, M. Comunian, J. P. Delahaye, ...

INTRODUCTION The objectives of the CLIC Test Facility (CTF) are to study the generation of short intense electron bunches using a laser driven photocathode in an RF gun, to generate 30 GHz RF power...