Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study (2008)
Shin, Taehoon, Hu, Houchun H, Pohost, Gerald M, Nayak, Krishna S
Abstract Background In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes....
Kim, Yoon-Chul, Nayak, Krishna S
No abstract available.
50 Myocardial signal behaviors of balanced SSFP imaging at 3 T (2008)
Sung, Kyunghyun, Nayak, Krishna S
No abstract available.
Makhijani, Mahender K, Pohost, Gerald M, Nayak, Krishna S
No abstract available.
2134 Validation of the spiral Fourier velocity encoding method (2008)
Carvalho, Joao LA, Nielsen, Jon F, Nayak, Krishna S
No abstract available.
2117 High-resolution 3D free-breathing coronary MR angiography using wideband SSFP at 3 Tesla (2008)
Lee, Hsu-Lei, Shankaranarayanan, Ajit, Pohost, Gerald M, Nayak, Krishna S
No abstract available.
Zun, Zungho, Wong, Eric C, Nayak, Krishna S
No abstract available.
Shin, Taehoon, Hu, Houchun H, Valencerina, Samuel S, Martinez, Luis, Pohost, Gerald M, Nayak, Krishna S
No abstract available.
1138 Measurement of beat-to-beat variability of stroke volume (2008)
Carvalho, Joao LA, Carvalho, Hervaldo S, Nayak, Krishna S
No abstract available.
1125 Spiral first-pass myocardial perfusion imaging at 3 Tesla: feasibility study (2008)
Shin, Taehoon, Sung, Kyunghyun, Pohost, Gerald M, Nayak, Krishna S
No abstract available.
1091 B1+ non-uniformity in 3 T CMR: patient study (2008)
Sung, Kyunghyun, Doyle, Eamon K, Valencerina, Samuel, Nayak, Krishna S
No abstract available.
Real-Time Color Flow MRI (2007)
Krishna S. Nayak, John M. Pauly, Adam B. Kerr, Bob S. Hu, Dwight G. Nishimura
A real-time interactive color flow MRI system capable of rapidly visualizing cardiac and vascular flow is described. Interleaved spiral phase contrast datasets are acquired continuously, while...
Krishna S. Nayak, Pedro A. Rivas, John M. Pauly, Greig C. Scott, Adam B. Kerr, Bob S. Hu, ...
A real-time interactive black-blood imaging system is described. Rapid blood suppression is achieved by exciting and dephasing slabs outside the imaging slice before each imaging excitation....
Real-Time Interactive Coronary MRA (2007)
Krishna S. Nayak, John M. Pauly, Phillip C. Yang, Bob S. Hu, Craig H. Meyer, Dwight G. Nishimura
An interactive real-time imaging system capable of rapid coronary artery imaging is described. High-resolution spiral and circular echo planar trajectories were used to achieve 0.8 � 1.6 mm 2...
Rapid Ventricular Assessment Using Real-Time Interactive Multislice MRI (2007)
Krishna S. Nayak, John M. Pauly, Dwight G. Nishimura, Bob S. Hu
A multislice real-time imaging technique is described which can provide continuous visualization of the entire left ventricle under resting and stress conditions. Three dynamically adjustable slices...
Introduction: Imaging Ultra-short T2 Species in the Brain (2007)
Krishna S. Nayak, John M. Pauly, Garry E. Gold, Dwight G. Nishimura