Barr, A J, Bachmann, S, Boimska, B, Bouclier, Roger, Braem, André, Camps, C, ...
We describe the construction, test and installation procedures, and the experience gained with the operation of a small but complete system of high rate Micro-Strip Gas Chambers, made on thin...
Progress with diamond over-coated microstrip gas chambers (1997)
Boimska, B, Bouclier, Roger, Capéans-Garrido, M, Dominik, Wojciech, Million, Gilbert, Ropelewski, Leszek, ...
We describe recent observations and measurements with Micro-Strip Gas Chambers coated, after manufacturing, with a thin diamond-like layer in order to increase their rate capability. Compared to the...
Development of a pressurized xenon wire chamber gamma camera for medical applications (1997)
Charpak, Georges, Barr, A J, Bouclier, Roger, Carugno, Giovanni, Tischhauser, Johann
Boimska, B, Bouclier, Roger, Dominik, Wojciech, Hoch, M, Million, Gilbert, Ropelewski, Leszek, ...
We describe recent observations and measurements realized with micro-strip gas chambers (MSGCs) manufactured on boro-silicate glass coated with a thin layer of diamond-like carbon (DLC) having a...
New observations with the gas electron multiplier (GEM) (1997)
Bouclier, Roger, Dominik, Wojciech, Hoch, M, Labbé, J C, Million, Gilbert, Ropelewski, Leszek, ...
We describe recent measurements realized with the Gas Electron Multiplier (GEM) mesh added as pre-amplification element to a multiwire and a micro-strip chamber. Large, stable combined gains are...
"Diamond" over-coated Microstrip Gas Chambers for high rate operation (1997)
Barr, A J, Boimska, B, Bouclier, Roger, Capéans-Garrido, M, Dominik, Wojciech, Hoch, M, ...
We describe the recent developments on the diamond-like carbon (DLC) over-coated Microstrip Gas Chambers made on drawn glass substrates. MSGC surface coating with thin DLC layer of stable and...
Operation of high rate microstrip gas chambers (1997)
Barr, A J, Boimska, B, Bouclier, Roger, Capéans-Garrido, M, Dominik, Wojciech, Manzin, G, ...
We describe recent measurements carried out in well controlled and reproducible conditions to help understanding the factors affecting the short and long term behaviour of Microstrip Gas Chambers....
Study of ageing and gain limits of microstrip gas chambers at high rates (1997)
Boimska, B, Bouclier, Roger, Capéans-Garrido, M, Claes, S, Dominik, Wojciech, Hoch, M, ...
The CMS experiment comprises MSGCs as one of the key detection elements for high luminosity tracking at LHC. In addition to the high dose rate of 10 mC/year per cm of strip, these detectors have to...
The gas electron multiplier (GEM) (1996)
Bouclier, Roger, Capéans-Garrido, M, Dominik, Wojciech, Hoch, M, Labbé, J C, Million, Gilbert, ...
We describe operating priciples and results obtained with a new detector component: the Gas Electrons Multiplier (GEM). Consisting of a thin composite sheet with two metal layers separated by a thin...
Ageing of microstrip gas chambers: problems and solutions (1996)
Bouclier, Roger, Capéans-Garrido, M, Garabatos, C, Manzin, G, Million, Gilbert, Ropelewski, Leszek, ...
The experimental set-up and the procedures used for studying the long-term behaviour of micro-strip gas chambers under sustained irradiation are described in detail. The most significant measurements...
High rate operation of micro-strip gas chambers (1996)
Bouclier, Roger, Capéans-Garrido, M, Hoch, M, Million, Gilbert, Ropelewski, Leszek, Sauli, Fabio, ...
High rate operation of micro-strip gas chambers on diamond-coated glass (1995)
Bouclier, Roger, Capéans-Garrido, M, Million, Gilbert, Ropelewski, Leszek, Sauli, Fabio, Temmel, T, ...
Very high rate operation of microstrip gas chambers can be achieved using slightly conducting substrates. We describe preliminary measurements realized with detectors manufactured on boro-silicate...
Optimization of design and beam test of microstrip gas chambers (1995)
Bouclier, Roger, Capéans-Garrido, M, Evans, J, Garabatos, C, Manzin, G, Million, Gilbert, ...
We describe recent experimental and theoretical work aimed at optimizing the geometry and the operation of micro-strip gas chambers in order to improve their performance and reliability. With the...
On some factors affecting discharge conditions in micro-strip gas chambers (1995)
Bouclier, Roger, Capéans-Garrido, M, Garabatos, C, Manzin, G, Million, Gilbert, Ropelewski, Leszek, ...
Development of micro-strip gas chambers for high rate operation (1995)
Bouclier, Roger, Capéans-Garrido, M, Garabatos, C, Manzin, G, Million, Gilbert, Ropelewski, Leszek, ...
High rate operation and lifetime studies with micro-strip gas chambers (1994)
Böhm, J, Bouclier, Roger, Capéans-Garrido, M, Garabatos, C, Manzin, G, Million, Gilbert, ...
Effects of outgassing from some materials on gas chamber ageing (1994)
Bouclier, Roger, Capéans-Garrido, M, Garabatos, C, Sauli, Fabio, Silander, K
Ageing studies with micro-strip gas chambers (1994)
Bouclier, Roger, Garabatos, C, Manzin, G, Million, Gilbert, Sauli, Fabio, Temmel, T, ...
Results of wire chamber ageing tests with CH$_{4}$- and DME-based gas mixtures (1994)
Bouclier, Roger, Capéans-Garrido, M, Garabatos, C, Heuer, R D, Jeanrenaud, M, Meyer, T C, ...
Optimization of microstrip gas chamber design and operating conditions (1994)
Beckers, T, Bouclier, Roger, Garabatos, C, Million, Gilbert, Sauli, Fabio, Shekhtman, L I
Development of microstrip gas chambers on substrata with electronic conductivity (1993)
Bouclier, Roger, Garabatos, C, Manzin, G, Sauli, Fabio, Shekhtman, L I, Temmel, T, ...
Performance of gas microstrip chambers on glass substrates with electronic conductivity (1993)
Bouclier, Roger, Million, Gilbert, Ropelewski, Leszek, Sauli, Fabio, Pestov, Yu N, Shekhtman, L I
High flux operation of microstrip gas chambers on glass and plastic supports (1992)
Bouclier, Roger, Florent, J J, Gaudaen, J, Million, Gilbert, Pasta, A, Ropelewski, Leszek, ...
Microstrip gas chambers on thin plastic supports (1992)
Bouclier, Roger, Florent, J J, Gaudaen, J, Million, Gilbert, Ropelewski, Leszek, Sauli, Fabio
Development of microstrip gas chambers on thin plastic supports (1991)
Florent, J J, Bouclier, Roger, Gaudaen, J, Sauli, Fabio, Shekhtman, L I
A very high light-yield imaging chamber (1990)
Bouclier, Roger, Bourdinaud, M, Charpak, Georges, Fonte, Paulo J R, Million, Gilbert, Sauli, Fabio, ...
The microstrip gas chamber (1990)
Angelini, F, Bellazzini, R, Brez, A, Massai, M M, Spandre, G, Torquati, M R, ...
A modular multidrift vertex detector (1990)
Bouclier, Roger, Charpak, Georges, Ropelewski, Leszek, Santiard, Jean-Claude, Solomey, Nickolas, Sauli, Fabio
Fast tracking detector using multidrift tubes (1990)
Bouclier, Roger, Charpak, Georges, Erskine, George A, Guérard, B, Santiard, Jean-Claude, Sauli, Fabio, ...
Recent developments of the multidrift tube (1990)
Bouclier, Roger, Gaudaen, J, Guz, Yu, Guérard, B, Santiard, Jean-Claude, Sauli, Fabio, ...
Development of a RICH detector for ultrarelativistic heavy ion collisions (1990)
Vasileiadis, G, Bouclier, Roger, Dominik, Wojciech, Gougas, Andreas, Ljubicic, A, Mongelli, M, ...
A modular multidrift vertex detector (1990)
Bouclier, Roger, Charpak, Georges, Gao, W X, Miné, P, Peisert, Anna, Santiard, Jean-Claude, ...
Operation of multidrift tubes with dimethyl ether (1990)
Bouclier, Roger, Charpak, Georges, Garabatos, José, Guérard, B, Santiard, Jean-Claude, Solomey, Nickolas, ...
Test-beam study of the performance of the microstrip gas avalanche chamber (1990)
Angelini, F, Bellazzini, R, Brez, A, Massai, M M, Spandre, G, Torquati, M R, ...
A linear drift chamber readout of a gated multistep avalanche chamber (1990)
Solomey, Nickolas, Bouclier, Roger, Charpak, Georges, Guz, Yu, Lamb, D C, Sauli, Fabio
Bouclier, Roger, Charpak, Georges, Cattai, A, Million, Gilbert, Peisert, Anna, Santiard, Jean-Claude, ...
Coupling of a $BaF_{2}$ scintillator to a TMAE photocathode and a low-pressure wire chamber (1990)
Anderson, D F, Bouclier, Roger, Charpak, Georges, Majewski, S R, Kneller, G F