S. Rollet

Publication List Details

Period

1996 - 2009

Number

22

Co-Authors

AVIDOS--a software package for European accredited aviation dosimetry (2009)

Latocha, M., Beck, P., Rollet, S.

AVIDOS is a computer code used for the dose assessment of aircraft crew exposed to cosmic radiation. The code employs a multiparameter model built upon simulations of cosmic radiation exposure done...

Overview of on-board measurements during solar storm periods (2009)

Beck, P., Dyer, C., Fuller, N., Hands, A., Latocha, M., Rollet, S., ...

Radiation exposure of aircraft crew caused by cosmic radiation is regulated in Europe by the European Community Council Directive 96/29/EURATOM and implemented into law in almost every country of the...

Comparison of codes assessing galactic cosmic radiation exposure of aircraft crew (2009)

Bottollier-Depois, J. F., Beck, P., Bennett, B., Bennett, L., Bütikofer, R., Clairand, I., ...

The assessment of the exposure to cosmic radiation onboard aircraft is one of the preoccupations of bodies responsible for radiation protection. Cosmic particle flux is significantly higher onboard...

Analysis of the CONRAD computational problems expressing only stochastic uncertainties: neutrons and protons (2008)

Gualdrini, G., Tanner, R. J., Agosteo, S., Pola, A., Bedogni, R., Ferrari, P., ...

Within the scope of CONRAD (A Coordinated Action for Radiation Dosimetry) Work Package 4 on Computational Dosimetry jointly collaborated with the other research actions on internal dosimetry, complex...

Measurements and simulations of the radiation exposure to aircraft crew workplaces due to cosmic radiation in the atmosphere (2007)

Beck, P., Latocha, M., Dorman, L., Pelliccioni, M., Rollet, S.

As required by the European Directive 96/29/Euratom, radiation exposure due to natural ionizing radiation has to be taken into account at workplaces if the effective dose could become more than 1 mSv...

Determinations of H*(10) and its dose components onboard aircraft (2007)

Lindborg, L., Beck, P., Bottolier-Depois, J. F., Latocha, M., Lillhök, J., Rollet, S., ...

Aircrew is in general receiving a higher average annual dose than other occupationally exposed personnel, and about half of the effective dose is deposited by high-LET neutron secondaries. A recent...

Calibration and background measurements with a tissue equivalent proportional counter (2007)

Autischer, M., Beck, P., Kindl, P., Latocha, M., Rollet, S.

A tissue-equivalent-proportional counter (TEPC) instrument has been used as the reference instrument for cosmic radiation measurement at flight altitudes by several institutes. For purposes of...

Measurement and simulation of lineal energy distribution at the CERN high energy facility with a tissue equivalent proportional counter (2007)

Rollet, S., Autischer, M., Beck, P., Latocha, M.

The response of a tissue equivalent proportional counter (TEPC) in a mixed radiation field with a neutron energy distribution similar to the radiation field at commercial flight altitudes has been...

The results of cosmic radiation in-flight TEPC measurements during the CAATER flight campaign and comparison with simulation (2007)

Latocha, M., Autischer, M., Beck, P., Bottolier–Depois, J. F., Rollet, S., Trompier, F.

The European-Commission-supported project DOSMAX (Dosimetry of Aircrew Exposure to Radiation During Solar Maximum) was aimed at measuring aircrew exposure to cosmic radiation on-board the aircraft...

Uncertainty budget for a whole body counter in the scan geometry and computer simulation of the calibration phantoms (2007)

Schlagbauer, M., Hrnecek, E., Rollet, S., Fischer, H., Brandl, A., Kindl, P.

At the Austrian Research Centers Seibersdorf (ARCS), a whole body counter (WBC) in the scan geometry is used to perform routine measurements for the determination of radioactive intake of workers....

MEASUREMENT AND SIMULATION OF LINEAL ENERGY DISTRIBUTION AT THE CERN HIGH ENERGY FACILITY WITH A TISSUE EQUIVALENT PROPORTIONAL COUNTER (2007)

Rollet, S., Autischer, M., Beck, P., Latocha, M.

The response of a tissue equivalent proportional counter (TEPC) in a mixed radiation field with a neutron energy distribution similar to the radiation field at commercial flight altitudes has been...

CALIBRATION AND BACKGROUND MEASUREMENTS WITH A TISSUE EQUIVALENT PROPORTIONAL COUNTER (2007)

Autischer, M., Beck, P., Kindl, P., Latocha, M., Rollet, S.

A tissue-equivalent-proportional counter (TEPC) instrument has been used as the reference instrument for cosmic radiation measurement at flight altitudes by several institutes. For purposes of...

THE RESULTS OF COSMIC RADIATION IN-FLIGHT TEPC MEASUREMENTS DURING THE CAATER FLIGHT CAMPAIGN AND COMPARISON WITH SIMULATION (2006)

Latocha, M., Autischer, M., Beck, P., Bottolier-Depois, J. F., Rollet, S., Trompier, F.

The European-Commission-supported project DOSMAX (Dosimetry of Aircrew Exposure to Radiation During Solar Maximum) was aimed at measuring aircrew exposure to cosmic radiation on-board the aircraft...

Shielding variation effects for 250 MeV protons on tissue targets (2005)

Brandl, A., Hranitzky, C., Rollet, S.

This paper provides results of computer simulation studies with the goal to analyse issues regarding radiation protection for personnel, patients and third persons involved in hadron therapy...

FLUKA simulation of TEPC response to cosmic radiation (2005)

Beck, P., Ferrari, A., Pelliccioni, M., Rollet, S., Villari, R.

The aircrew exposure to cosmic radiation can be assessed by calculation with codes validated by measurements. However, the relationship between doses in the free atmosphere, as calculated by the...

Dosimetric considerations on TEPC fluka-simulation and measurements (2004)

Rollet, S., Beck, P., Ferrari, A., Pelliccioni, M., Autischer, M.

The response of a tissue equivalent proportional counter (TEPC) has been simulated with the Monte Carlo transport code FLUKA. The absorbed dose distribution of lineal energy y has been determined for...

Radiation calculations for the ATLAS detector and experimental hall (1996)

Ferrari, A, Potter, K M, Rollet, S, Sala, P R

This paper describes the calculations performed to characterise the radiation field in the ATLAS detector at the LHC and to design the shielding of the detector and experimental areas. After a short...