A 200 × 200 CCD Image Sensor Fabricated On High-Resistivity Silicon (2007)
S.E. Holland, G. Goldhaber, D. E. Groom, W. W. Moses, C.R. Pennypacker, S. Perlmutter, ...
A charge coupled device (CCD) image sensor fabricated on high-resistivity silicon is described. The resistivity, about 10,000 \Omega\Gamma000 allows for operation of the CCD with the entire 300 ¯m...
Initial results of a positron tomograph for prostate imaging (2004)
Huber, J.S., Choong, W.S., Moses, W.W., Qi, J., Hu, J., Wang, G.C., ...
We present the status and initial images of a positron tomograph for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis)....
A retrospective on the LBNL PEM project (2004)
Huber, J.S., Moses, W.W., Wang, G.C., Derenzo, S.E., Huesman, R.H., Qi, J., ...
We present a retrospective on the LBNL Positron Emission Mammography (PEM) project, looking back on our design and experiences. The LBNL PEM camera utilizes detector modules that are capable of...
Calibration of a PEM detector with depth of interaction measurement (2004)
Huber, J.S., Moses, W.W., Maltz, J.S.
We present an in situ calibration technique for the LBNL positron emission mammography (PEM) detector module that is capable of measuring depth of interaction (DOI). The detector module consists of...
Weng, M., Mandelli, E., Moses, W.W., Derenzo, S.E.
A high-speed, low-noise 16-channel amplifier IC has been fabricated in the HP 0.5 mm CMOS process. It is a prototype for use with a PET detector which uses a 4x4 avalanche photodiode (APD) array...
Labr3:Ce scintillators for gamma ray spectroscopy (2002)
Shah, K.S., Glodo, J., Klugerman, M., Moses, W.W., Derenzo, S.E., Weber, M.J.
In this paper, we report on a relatively new scintillator - LaBr3 for gamma ray spectroscopy. Crystals of this scintillator have been grown using Bridgman process. This material when doped with...
The electronics system for the LBNL positron emission tomography (PEM) camera (2000)
Moses, W.W., Young, J.W., Baker, K., Jones, W., Lenox, M., Ho, M.H., ...
We describe the electronics for a high performance Positron Emission Mammography (PEM) camera. It is based on the electronics for a human brain PET camera (the Siemens/CTI HRRT), modified to use a...
Conceptual design of a compact positron tomograph for prostate imaging (2000)
Huber, J.S., Derenzo, S.E., Qi, J., Moses, W.W., Huesman, R.H., Budinger, T.F.
We present a conceptual design of a compact positron tomograph for prostate imaging using a pair of external curved detector banks, one placed above and one below the patient. The lower detector bank...
A LSO scintillator array for a PET detector module with depth of interaction measurement (2000)
Huber, J.S., Moses, W.W., Andreaco, M.S., Petterson, O.
We present construction methods and performance results for a production scintillator array of 64 optically isolated, 3 mm x 3 mm x 30 mm sized LSO crystals. This scintillator array has been...
Characterization of a 64 channel PET detector using photodiodes for crystal identification (1996)
Moses, W W, Derenzo, Stephen E, Ho, M H, Andreaco, M S, Williams, C W, Paulus, M J, ...
Scintillator characterization using the LBL pulsed x-ray facility (1995)
Moses, W W, Derenzo, Stephen E, Weber, M J, Blankespoor, S C, Ho, M H, West, A C